THE COLLECTION WAS SOLD IN 2011
This collection of 48 x-ray tubes and 2 radio tubes was owned by James F. Lee, an inventor and manufacturer of x-ray tubes beginning in the late 1920's through the 1930's. His manufacturing lab was located in Palo Alto, CA (now Menlo Park). The tubes he manufactured were very high quality and, according to letters from purchasers, even better than major manufacturers like Coolidge.
<<< >>>
NO.
|
MANUFACTURER
|
LENGTH “
|
CONT?
|
COMMENTS
|
1
| Coolidge |
19
|
N
| |
2
| Lee |
20
|
N
| S/N: 277180 etched into glass |
3
| Crookes ? |
21
|
NT
| |
4
| Mueller – Media |
24
|
N
| German – Helium S/N: 300973 2.5 KW |
5
| Coolidge Victor |
17
|
Y
| S/N: CA 153 |
6
| Mueller – Media Metalix |
25
|
Y
| German – Helium S/N: 319067 10 KW |
7
| Coolidge GE |
18
|
Y
| RD - lead glass – 7 lb 3 oz |
8
| Coolidge |
19
|
N
| XP-1-4 S/N: X5847 (this may be an experimental tube) |
9
| Lee Four Focus |
24
|
Y
| Patent applied for S/N: 12566 |
10
| Lee |
28
|
Y
| |
11
| Lee |
20
|
Y
| |
12
| Lee |
24
|
Y
| 1” long black surface scratch on glass |
13
| Lee |
13
|
Y
| |
14
| Lee |
22
|
Y
| |
15
| Lee |
22
|
Y
| Patent 2,123,607 |
16
| Coolidge |
24
|
Y
| BROAD S/N: 73582 |
17
| Lee |
20
|
Y
| No anode cap |
18
| Lee 2 Focus X-Ray Tube |
21
|
Y
| Patent Pending S/N: 12738 #2 Key included |
19
| Lee |
32
|
Y
| No anode cap |
20
| Coolidge Victor 30MA |
19
|
N
| S/N: 77480 |
21
| Lee |
8.5
|
Y
| No anode cap |
22
| Lee |
24
|
Y
| |
23
| Eureka |
9.25
|
Y
| 7-70P Patent 1,590,971 S/N: 6217 no cathode cap |
24
| GE |
28
|
Y
| “Dirt” or rust inside of tube |
25
| Lee |
9.25
|
Y
| |
26
| Westinghouse Deep Therapy |
33
|
N
| |
27
| Original Muller X-Ray Tube |
23
|
N
| S/N: 272806 2861 dirt on inside of glass |
28
| Lee |
23
|
Y
| |
29
| Lee X-Ray Tube |
17.5
|
Y
| 1.5 KW |
30
| Lee |
17.5
|
Y
| |
31
| Coolidge Victor |
13
|
N
| 10 MA S/N: RD 80529 |
32
| Coolidge GE |
22
|
Y
| Medium focus S/N: 44141 |
33
| Coolidge Victor |
22
|
Y
| Medium S/N: 60584 both ends damaged |
34
| Coolidge GE |
20
|
Y
| XP-1 S/N: X5990 Experimental? |
35
| Lee Four Focus X-Ray Tube |
21
|
Y
| S/N: 12673 Patent Pending |
36
| Lee |
12.5
|
Y
| |
37
| Lee |
14.5
|
Y
| Anode cap missing |
38
| Lee |
10.25
|
Y
| |
39
| Lee |
33
|
Y
| Corrosion on one end – coating on inside of bulb |
40
| Coolidge Victor |
20
|
Y
| 100 MA S/N: 4R 1192 anode end loose dirt inside glass |
41
| Lee |
19
|
Y
| Anode end missing - spider webs and some dirt inside tube |
42
| Kenex |
31
|
Y
| S/N: 243394 Patented 69.1925 200 KV Made in Germany |
43
| Coolidge GE |
34
|
N
| S/N: 2U 6690 8 M.A. 200,000 volts Both ends loose - dirt, etc. dirty |
44*
| General Electric |
25
|
Y
| KC-4 S/N: 7195 rust on inside parts |
45*
| General Electric |
25
|
Y
| KC-4 S/N: 20378 rust on inside parts |
46
| Lee |
32.5
|
Y
| No. 40016 on inside metal - both end caps missing – dirt on inside of glass |
47
| Lee |
22
|
Y
| |
48
| BELLVUE |
20
|
NT
| S/N: 109 Crookes type? |
49
| Macalaster Wiggin Co. |
21
|
NT
| Transformer Tube S/N: 8??58 |
50
| Lee |
28
|
Y
|
* Not an x-ray tube but a radio tube.
TUBE PHOTOS
(left click on image to magnify)
![]() |
| 01 |
![]() |
| 02 |
![]() |
| 03 |
| 04 |
![]() |
| 05 |
![]() |
| 06 |
![]() |
| 07 |
![]() |
| 08 |
![]() |
| 09 |
| 10 |
![]() |
| 11 |
![]() |
| 12 |
![]() |
| 13 |
![]() |
| 14 |
![]() |
| 15 |
![]() |
| 16 |
![]() |
| 17 |
![]() |
| 18 |
| 19 |
![]() |
| 20 |
![]() |
| 21 |
| 22 |
![]() |
| 23 |
| 24 |
![]() |
| 25 |
![]() |
| 26 |
![]() |
| 27 |
![]() |
| 28 |
![]() |
| 29 |
![]() |
| 30 |
![]() |
| 31 |
![]() |
| 32 |
![]() |
| 33 |
![]() |
| 34 |
![]() |
| 35 |
![]() |
| 36 |
![]() |
| 37 |
![]() |
| 38 |
![]() |
| 39 |
![]() |
| 40 |
![]() |
| 41 |
![]() |
| 42 |
![]() |
| 43 |
![]() |
| 44* |
![]() |
| 45* |
![]() |
| 46 |
![]() |
| 47 |
![]() |
| 48 |
![]() |
| 49 |
| 50 |